Materials & Fabrication
Welding & Fabrication Supplies
Welding consumables are specified by classification, not by description. "E7018" defines a deposited chemistry and a mechanical property through the AWS system, and the same electrode from two factories can differ in hydrogen content, coating adhesion and out-of-position behaviour — which is why the classification includes a diffusible hydrogen designator (H4, H8, H16) that buyers routinely leave out of the inquiry.
For welding machines, the specification that decides usability is the duty cycle at a stated ambient temperature, the input voltage, and the process capability. A 200A machine rated at 60% duty at 40°C behaves differently from one rated at 35% — and the second number is usually the one that is omitted from the marketing sheet.
Consumable storage is part of the product. Low-hydrogen electrodes absorb moisture once the packaging is opened, and a hermetically sealed container or a re-drying oven is not optional for critical work. Chinese suppliers can provide vacuum-sealed packaging and batch certificates, and both should be requested explicitly for structural or pressure work.
Category at a glance
Welding & Fabrication
- Product types mapped
- 5
- Dedicated sub-pages
- 0
- Reply commitment
- 1 business day
- Related sourcing services
- Product SourcingSupplier ComparisonQuality Planning
We supply to your specification. We do not manufacture this category and we do not inspect goods — how quality risk is handled is set out separately.
- 15 product familiesone purchase order
- Exported from NingboEXW / FOB / CIF / DDP
- One specification sheetquoted line by line
- Reply in 1 business dayfrom a named person
Coverage
What this family covers
Everything below is supplied, whether or not it has its own page. Linked items have a dedicated page with their own specification detail.
Not listed? The category boundary is a sourcing convenience, not a limit. Describe the item and we will tell you whether it fits.
Specification
What to write down before you ask for an offer
These are the fields that move a welding & fabrication quotation. You do not need all of them to start an inquiry — but each one you leave out comes back as an assumption, and the assumption will be the factory's, not yours.
Send these details- 01
Classification
AWS A5.1 E7018 H4R, AWS A5.18 ER70S-6, or the EN ISO equivalent, complete with designators.
- 02
Diameter and packing
2.5/3.2/4.0mm, spool or coil weight, and whether vacuum-sealed packaging is required.
- 03
Diffusible hydrogen
H4, H8 or H16 for low-hydrogen electrodes, and the storage condition assumed.
- 04
Base material
Carbon steel, stainless, duplex or hardfacing, and the matching consumable grade.
- 05
Machine duty cycle
Percentage at a stated ambient temperature, and the input voltage and phase.
- 06
Process
MIG, TIG, MMA, FCAW or submerged arc, and whether the machine must do several.
- 07
Certificates
Batch test certificate, classification approval, and third-party approval if the project requires it.
- 08
Storage and shelf life
Packaging type, shelf life, and the re-drying condition before use.
Where it goes wrong
What actually causes problems in this category
Specific to welding & fabrication, not generic advice. Each of these is something we ask about before a factory is approached.
The classification is the specification
E7018 is a family, and the suffix designators — H4 for diffusible hydrogen, R for moisture resistance — carry the properties that matter in structural work. A quotation for "7018 electrodes" without designators is a quotation for an unspecified product. We quote the full classification and ask the factory to confirm it on the certificate.
Moisture is the failure mode nobody sees
Low-hydrogen electrodes left in an open packet absorb moisture, and the resulting weld has hydrogen that shows up as cracking days later. Vacuum-sealed packaging, correct storage on site and re-drying before use are all part of the specification. For structural or pressure work, the packaging method belongs on the order, not in a storage procedure nobody reads.
Duty cycle is the honest measure of a machine
A machine that claims 250A but delivers it at 30% duty is a 180A machine in continuous fabrication. The duty cycle at 40°C ambient is the number to compare, and it is frequently missing from Chinese-language specifications while being present on the export datasheet. We ask for it explicitly and compare on that basis.
Consumables and machines should be quoted together
A machine is only as good as the wire or electrode it runs, and a mismatched combination produces porosity that gets blamed on the operator. When we quote a welding package, we quote the machine, the consumable specification and the recommended settings as one set, so that the buyer is not left to discover the incompatibility during commissioning.
Common questions
Welding & Fabrication — asked often
Answers include what we cannot do, where that is the honest answer.
Can you supply electrodes with batch test certificates?
Yes, where the factory issues them, and we confirm the certificate type at inquiry. Batch certificates trace the consumable to a production lot with its mechanical properties and, where applicable, diffusible hydrogen result. If your project requires third-party approval such as ABS or TÜV, that must be stated before production because it cannot be added to a completed batch.
What duty cycle should a fabrication shop specify?
It depends on the actual arc-on time. Production shops running continuous seams need 60% at 40°C or better; maintenance and site work can usually accept 35-40%. Undersizing leads to thermal trips that get blamed on the machine, and oversizing adds weight with no benefit. The arc-on ratio from a typical shift is the number that decides it.
Do you supply welding machines for 110V supply?
Some models are available in 110V builds, typically with lower maximum output because of the current limit. The input voltage and phase must be stated at inquiry. For site work on 110V, the machine also needs the relevant site certification, which not every export model carries.
How should electrodes be stored after delivery?
Sealed in their original packaging in a dry store, and for low-hydrogen types, re-dried at the manufacturer's stated temperature and time before use, then held in a heated quiver. This is the consumable maker's instruction, not ours, and the specific figures should come with the batch documentation. We can request that the factory supply its storage and re-drying instructions with the shipment.
Related
How this category is usually bought
Services that apply to welding & fabrication, and the industries where it is a recurring purchase.
Industrial Product Sourcing
Find industrial products against a written specification, with comparable supplier quotations and clearly stated requirements.
Learn moreSupplier Comparison & Offer Analysis
Compare supplier offers on the same specification, quantity and delivery basis, with differences and exclusions made clear.
Learn moreSpecification & Quality Planning
Clarify specifications, acceptance requirements and sample approval before ordering. Independent inspection and testing remain with your appointed providers.
Learn moreWelding & Fabrication from China, priced and shipped
Send the specification, a drawing, or a photograph of the part you are replacing. A named person replies within one business day — with what we can confirm and what we still need from you.
We reply within 1 business day — from a named person, not an auto-responder. Your requirement is confirmed first; the quotation follows once details are agreed.